{"id":21409,"date":"2025-09-01T16:09:35","date_gmt":"2025-09-01T14:09:35","guid":{"rendered":"https:\/\/silla.industries\/docs\/prism-howto-cluster\/"},"modified":"2025-09-12T15:19:44","modified_gmt":"2025-09-12T13:19:44","password":"","slug":"prism-howto-cluster","status":"publish","type":"docs","link":"https:\/\/silla.industries\/en\/docs\/prism-howto-cluster\/","title":{"rendered":"Cluster &#8211; Installation and Configuration"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Introduction<\/h2>\n\n<p>Cluster is the functionality that allows multiple Prisms to communicate with each other when connected to the same system.<\/p>\n\n<p>This functionality is <strong>critical<\/strong> for:<\/p>\n\n<ul class=\"wp-block-list\">\n<li><span style=\"text-decoration: underline;\">Load balancing<\/span>\n<ul class=\"wp-block-list\">\n<li>when connected to the same system, the Prisms must communicate with each other in order to share the available power<\/li>\n\n\n\n<li>without Cluster multiple Prisms on the same system CANNOT have load balancing enabled.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><span style=\"text-decoration: underline;\">HoReCa Management<\/span>\n<ul class=\"wp-block-list\">\n<li>in case of RFID card recharge authorization with the HoReCa service, the Prisms can share the list of cards authorized for recharge. Therefore, it is not necessary to activate the cards on each Prism, but they will be activated for all Prisms in the Cluster. <\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n<div class=\"alert\">\n<b>Cluster functionality is available from version 2.7.X.<\/b><br\/>If your Prisms have a lower version, connect them to the Internet and perform an upgrade (follow the Prism installation manual)\n<\/div>\n\n<h3 class=\"wp-block-heading\">Design of a Prism Cluster<\/h3>\n\n<p>When designing a Cluster, it is necessary to take into consideration the size of the plant on which the Cluster will be installed.<\/p>\n\n<p>For <strong>Clusters up to 5<\/strong> Prism the Smart Meter supplied with Prism is adequate as it can measure currents up to 100A.<\/p>\n\n<div class=\"note\">Each Prism can charge up to 32A, so with the Smart Meter included with Prism, up to 3 Prisms can charge at maximum current. Considering that many cars on the market do not charge at 32A and that not all cars will always be connected at the same time, the Smart Meter included with Prism is recommended for Clusters of up to 5 Prisms. <\/div>\n\n<p>For <strong>Clusters of up to 30 Prisms<\/strong>, you should request 1000A TA sensors, which are available for purchase in the online shop as an additional accessory.<\/p>\n\n<div class=\"alert\"><b>Make sure you have the appropriate Smart Meter for the size of the system<\/b> where the Cluster will be installed.<br\/>Refer to the <a href=\"https:\/\/silla.industries\/en\/docs\/prism-howto-smart-meter-guida-installazione-ed-uso\/\">Installation and User Guide<\/a>.<\/div>\n\n<p>For <strong>Clusters over 30 Prisms<\/strong> contact Silla support to schedule Cluster installation and configuration.<\/p>\n\n<div class=\"alert\"><b>It is NOT possible to install more than one Cluster on the same system<\/b>. In case of installation of more than <b>30 Prisms on the same system<\/b> contact Silla service. <\/div>\n\n<h2 class=\"wp-block-heading\">Installation<\/h2>\n\n<p>For installation of the Cluster Prisms, follow all directions in the Prism Installation Manual.<\/p>\n\n<p>Only one of the Prisms, which we will call <strong>&#8220;Primary Prism,&#8221;<\/strong> will have the sensor for load balancing connected. All other Prisms will not have the sensor connected and we will call them <strong>&#8220;Secondary Prisms<\/strong>. <strong>&#8220;<\/strong> <\/p>\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/silla.industries\/wp-content\/uploads\/2023\/05\/IMG-Schema_collegamento_Cluster10_rete-1600-1024x458.jpg\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"458\" src=\"https:\/\/silla.industries\/wp-content\/uploads\/2023\/05\/IMG-Schema_collegamento_Cluster10_rete-1600-1024x458.jpg\" alt=\"\" class=\"wp-image-14994\" srcset=\"https:\/\/silla.industries\/wp-content\/uploads\/2023\/05\/IMG-Schema_collegamento_Cluster10_rete-1600-1024x458.jpg 1024w, https:\/\/silla.industries\/wp-content\/uploads\/2023\/05\/IMG-Schema_collegamento_Cluster10_rete-1600-300x134.jpg 300w, https:\/\/silla.industries\/wp-content\/uploads\/2023\/05\/IMG-Schema_collegamento_Cluster10_rete-1600-768x343.jpg 768w, https:\/\/silla.industries\/wp-content\/uploads\/2023\/05\/IMG-Schema_collegamento_Cluster10_rete-1600-360x161.jpg 360w, https:\/\/silla.industries\/wp-content\/uploads\/2023\/05\/IMG-Schema_collegamento_Cluster10_rete-1600-1536x686.jpg 1536w, https:\/\/silla.industries\/wp-content\/uploads\/2023\/05\/IMG-Schema_collegamento_Cluster10_rete-1600-1200x536.jpg 1200w, https:\/\/silla.industries\/wp-content\/uploads\/2023\/05\/IMG-Schema_collegamento_Cluster10_rete-1600-1320x590.jpg 1320w, https:\/\/silla.industries\/wp-content\/uploads\/2023\/05\/IMG-Schema_collegamento_Cluster10_rete-1600-600x268.jpg 600w, https:\/\/silla.industries\/wp-content\/uploads\/2023\/05\/IMG-Schema_collegamento_Cluster10_rete-1600.jpg 1600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n<div class=\"warning\">Installation of the Prism sensor should be done according to the directions in the Prism manual. The sensor should always be placed downstream of the general meter, so that it can read ALL loads at the meter (Prism and any PV system included). <\/div>\n\n<p>In order to connect the Prisms together to create a Cluster, <strong>all Solar Prisms must be connected to the same local area network via Ethernet cable.<\/strong><\/p>\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/silla.industries\/wp-content\/uploads\/2023\/05\/IMG-Schema_collegamento_Cluster10_ethernet-1600-1024x333.jpg\"><img decoding=\"async\" width=\"1024\" height=\"333\" src=\"https:\/\/silla.industries\/wp-content\/uploads\/2023\/05\/IMG-Schema_collegamento_Cluster10_ethernet-1600-1024x333.jpg\" alt=\"\" class=\"wp-image-14999\" srcset=\"https:\/\/silla.industries\/wp-content\/uploads\/2023\/05\/IMG-Schema_collegamento_Cluster10_ethernet-1600-1024x333.jpg 1024w, https:\/\/silla.industries\/wp-content\/uploads\/2023\/05\/IMG-Schema_collegamento_Cluster10_ethernet-1600-300x98.jpg 300w, https:\/\/silla.industries\/wp-content\/uploads\/2023\/05\/IMG-Schema_collegamento_Cluster10_ethernet-1600-768x250.jpg 768w, https:\/\/silla.industries\/wp-content\/uploads\/2023\/05\/IMG-Schema_collegamento_Cluster10_ethernet-1600-360x117.jpg 360w, https:\/\/silla.industries\/wp-content\/uploads\/2023\/05\/IMG-Schema_collegamento_Cluster10_ethernet-1600-1536x500.jpg 1536w, https:\/\/silla.industries\/wp-content\/uploads\/2023\/05\/IMG-Schema_collegamento_Cluster10_ethernet-1600-1200x391.jpg 1200w, https:\/\/silla.industries\/wp-content\/uploads\/2023\/05\/IMG-Schema_collegamento_Cluster10_ethernet-1600-1320x430.jpg 1320w, https:\/\/silla.industries\/wp-content\/uploads\/2023\/05\/IMG-Schema_collegamento_Cluster10_ethernet-1600-600x195.jpg 600w, https:\/\/silla.industries\/wp-content\/uploads\/2023\/05\/IMG-Schema_collegamento_Cluster10_ethernet-1600.jpg 1600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n<h2 class=\"wp-block-heading\">Configuration<\/h2>\n\n<p>The configuration of a Cluster occurs with these steps:<\/p>\n\n<ol class=\"wp-block-list\">\n<li><strong>Connection to the Prisms<\/strong>.<\/li>\n\n\n\n<li><strong>Primary Prism Configuration<\/strong>.<\/li>\n\n\n\n<li><strong>Secondary Prism Configuration<\/strong>.<\/li>\n\n\n\n<li><strong>Cluster Configuration<\/strong>.<\/li>\n<\/ol>\n\n<p><strong>Materials Needed<\/strong>:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>PC (laptop or fixed) connected to the same network as the Prisms.<\/li>\n\n\n\n<li>Installation manual for each Prism.\n<ul class=\"wp-block-list\">\n<li>Need login credentials in the label under &#8220;Product Identification.&#8221;<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n<h3 class=\"wp-block-heading\"><strong>Connection to Prisms  <\/strong><\/h3>\n\n<p>For a Cluster to function properly, it is necessary:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>Connect all Prisms to the <strong>same local area network<\/strong>.<\/li>\n\n\n\n<li>Open <strong>TCP ports 5555 <\/strong>and<strong> 5698<\/strong>.<\/li>\n\n\n\n<li>Set<strong> static IP<\/strong> addresses<strong> for all Prisms<\/strong>.<\/li>\n<\/ul>\n\n<div class=\"note\">In the case of corporate networks, contact the network administrator to configure the network and find out the IP addresses of the Prisms.<\/div>\n\n<p>Before proceeding, it is necessary to<strong> identify the IP addresses of all Prisms<\/strong> connected to the local network.  <\/p>\n\n<p>Prisms are identifiable by their <strong>MAC address<\/strong>, which is of the type <strong>78:D4:F1:11:XX:XX <\/strong><strong>(*<\/strong>). The MAC address can be found on the credentials label in the Installation Manual of each Prism. <\/p>\n\n<div class=\"warning\"><b>(*)<\/b> The MAC address on the Prism Manual label is relative to the WiFi interface, so <b>the last byte of the MAC will be different from the one on the label<\/b>. If needed, contact Silla support to get the Ethernet interface MAC list. <\/div>\n\n<p>Once you have obtained all the Prism IP addresses you can proceed with the configuration, making sure you have them in range:<\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>IP addresses<\/strong> and <strong>serial numbers<\/strong> of each Prism.<\/li>\n\n\n\n<li><strong>Installation Manual for each Prism<\/strong>, where there is a<strong>label with the credentials <\/strong>to access the Prisms.<\/li>\n<\/ul>\n\n<h3 class=\"wp-block-heading\"><strong>Primary Prism Configuration<\/strong><\/h3>\n\n<p>Once the network is set up, you can proceed with the configuration of Prism:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>Go to the Primary Prism Guided Configuration page <strong>&lt;IP_Primary&gt;<\/strong> \/welcome and login with the &#8220;<strong>installer<\/strong>&#8221; credentials listed on the label.<\/li>\n\n\n\n<li>Select &#8220;<strong>Primary Prism (Cluster)<\/strong>.&#8221;<\/li>\n\n\n\n<li>Save<strong> IP Address<\/strong> and <strong>PIN<\/strong>.<\/li>\n<\/ul>\n\n<div class=\"warning\"><b>DO NOT close this Guided Configuration page<\/b>, you will need to return to it after the Secondary Prisms are configured.<\/div>\n\n<h3 class=\"wp-block-heading\"><strong>Secondary Prism Configuration<\/strong><\/h3>\n\n<ul class=\"wp-block-list\">\n<li>Go to the Secondary Prism Configuration Wizard page <strong>&lt;IP_Secondary&gt;<\/strong> \/welcome and login with the &#8220;<strong>installer<\/strong>&#8221; credentials listed on the label.<\/li>\n\n\n\n<li>Select &#8220;<strong>Secondary Prism (Cluster)<\/strong>.&#8221;<\/li>\n\n\n\n<li>Enter the <strong>IP address<\/strong> and <strong>PIN code <\/strong>of the Primary Prism.<\/li>\n\n\n\n<li>Verify that the <strong>connection test is successful<\/strong> and click &#8220;<strong>Go to dashboard<\/strong>&#8221; to complete the configuration.<\/li>\n<\/ul>\n\n<div class=\"warning\">Repeat this procedure for each Secondary Prism. Once all Secondary Prisms have been configured, go to the next chapter. <\/div>\n\n<h3 class=\"wp-block-heading\"><strong>Primary Prism Configuration Completion<\/strong><\/h3>\n\n<ul class=\"wp-block-list\">\n<li>Reopen the Primary Prism configuration wizard page.<\/li>\n\n\n\n<li>Click on the<strong>&#8220;Start Discovery<\/strong>&#8221; button.<\/li>\n\n\n\n<li><strong>Verify that all Secondary Prisms are in place<\/strong>.\n<ul class=\"wp-block-list\">\n<li>Remove any Prisms that you do NOT want to include in the Cluster.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>Click on<strong>&#8220;Finish Discovery<\/strong>.&#8221;<\/li>\n\n\n\n<li>Click on the<strong>&#8220;Go to Dashboard<\/strong>&#8221; button to finish the configuration.<\/li>\n\n\n\n<li>Now that the configuration is complete the Cluster is ready for use! Follow the &#8220;Using&#8221; chapter for more details. <\/li>\n<\/ul>\n\n<h2 class=\"wp-block-heading\">Use<\/h2>\n\n<h3 class=\"wp-block-heading\"><strong>Load balancing<\/strong><\/h3>\n\n<p>Load balancing, which must be enabled by the Primary Prism, allows all Prisms in the Cluster not to exceed the maximum power of the system.<\/p>\n\n<div class=\"alert\"><b>It is NOT possible to install more than one Cluster on the same system<\/b>. In case of installation of more than 30 Prisms on the same system contact Silla service. <\/div>\n\n<h4 class=\"wp-block-heading\"><strong>Set the maximum power<\/strong><\/h4>\n\n<p>Setting the maximum power should be done through the Guided Primary Prism Configuration.<\/p>\n\n<h4 class=\"wp-block-heading\"><strong>How load balancing works<\/strong><\/h4>\n\n<p>Load balancing adjusts the power of each Prism to avoid exceeding the maximum power. In particular, Prism will try to: <\/p>\n\n<ul class=\"wp-block-list\">\n<li>Load as many cars as possible.\n<ul class=\"wp-block-list\">\n<li>Power is divided equally among all cars.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>Prioritize first-come, first-served.\n<ul class=\"wp-block-list\">\n<li>In case there is not enough power to charge all connected cars, the charging of the one who connected the car last will be paused.<\/li>\n\n\n\n<li>Charging will resume as soon as sufficient power is available.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n<div class=\"note\">Remember that by regulation the minimum power to be able to charge the car is:<ul><li>1.4 kW in single phase<\/li><li>4 kW in three-phase<\/li><\/ul>\nIf there is not this minimum power, charging will not start.<\/div>\n\n<h3 class=\"wp-block-heading\">RFID Authorization<\/h3>\n\n<p>In case you want to authorize recharging through RFID cards, to allow recharging only to authorized users, follow the <a href=\"https:\/\/silla.industries\/en\/service-horeca\/\" data-type=\"post\" data-id=\"2171\">HoReCa Guide<\/a>.<\/p>\n\n<h3 class=\"wp-block-heading\"><strong>Charging mode<\/strong><\/h3>\n\n<p>In case of Cluster, the charging mode will be modifiable only by the Primary Prism and will be the same for the whole Cluster.<\/p>\n\n<div class=\"note\">It is not possible to choose a different charging mode for each Prism in the Cluster.<\/div>\n\n<h4 class=\"wp-block-heading\">Normal Mode<\/h4>\n\n<p>In Normal mode, the Prisms will use all the power they need, always staying below the maximum power of the meter.<\/p>\n\n<h4 class=\"wp-block-heading\">Solar mode<\/h4>\n\n<p>In Solar mode, the Prisms will use only the excess power from the PV system that would be sold to the grid.<\/p>\n\n<div class=\"note\">Refer to the Prism Solar Installation, Operation and Maintenance Manual for more information on charging methods.<\/div>\n\n<h3 class=\"wp-block-heading\"><strong>Error handling<\/strong><\/h3>\n\n<ol class=\"wp-block-list\">\n<li>What happens in case of errors of the Primary Prism sensor?\n<ul class=\"wp-block-list\">\n<li>In case the sensor has problems reading, all Prisms will lower the charging current to the minimum, that is, 6A.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>What happens if a Secondary Prism has communication problems with the Primary?\n<ul class=\"wp-block-list\">\n<li>In this case, the Secondary Prism will automatically set the charging current to the minimum, that is, 6A.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n<div class=\"note\">Remember that by regulation the minimum power to be able to charge the car is:<ul><li>1.4 kW in single phase<\/li><li>4 kW in three-phase<\/li><\/ul>\nIf there is not this minimum power, charging will not start.<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Introduction Cluster is the functionality that allows multiple Prisms to communicate with each other when connected to the same system. This functionality is critical for: Cluster functionality is available from version 2.7.X.If your Prisms have a lower version, connect them to the Internet and perform an upgrade (follow the Prism installation manual) Design of a Prism Cluster When designing a Cluster, it is necessary to take into consideration the size of the plant on which the Cluster will be installed. For Clusters up to 5 Prism the Smart Meter supplied with Prism is adequate as it can measure currents up to 100A. Each Prism can charge up to 32A, so with the Smart Meter included with Prism, up to 3 Prisms can charge at maximum current. Considering that many cars on the market do not charge at 32A and that not all cars will always be connected at the same time, the Smart Meter included with Prism is recommended for Clusters of up to 5 Prisms. For Clusters of up to 30 Prisms, you should request 1000A TA sensors, which are available for purchase in the online shop as an additional accessory. Make sure you have the appropriate Smart Meter for the size of the system where the Cluster will be installed.Refer to the Installation and User Guide. For Clusters over 30 Prisms contact Silla support to schedule Cluster installation and configuration. It is NOT possible to install more than one Cluster on the same system. In case of installation of more than 30 Prisms on the same system contact Silla service. Installation For installation of the Cluster Prisms, follow all directions in the Prism Installation Manual. Only one of the Prisms, which we will call &#8220;Primary Prism,&#8221; will have the sensor for load balancing connected. All other Prisms will not have the sensor connected and we will call them &#8220;Secondary Prisms. &#8220; Installation of the Prism sensor should be done according to the directions in the Prism manual. The sensor should always be placed downstream of the general meter, so that it can read ALL loads at the meter (Prism and any PV system included). In order to connect the Prisms together to create a Cluster, all Solar Prisms must be connected to the same local area network via Ethernet cable. Configuration The configuration of a Cluster occurs with these steps: Materials Needed: Connection to Prisms For a Cluster to function properly, it is necessary: In the case of corporate networks, contact the network administrator to configure the network and find out the IP addresses of the Prisms. Before proceeding, it is necessary to identify the IP addresses of all Prisms connected to the local network. Prisms are identifiable by their MAC address, which is of the type 78:D4:F1:11:XX:XX (*). The MAC address can be found on the credentials label in the Installation Manual of each Prism. (*) The MAC address on the Prism Manual label is relative to the WiFi interface, so the last byte of the MAC will be different from the one on the label. If needed, contact Silla support to get the Ethernet interface MAC list. Once you have obtained all the Prism IP addresses you can proceed with the configuration, making sure you have them in range: Primary Prism Configuration Once the network is set up, you can proceed with the configuration of Prism: DO NOT close this Guided Configuration page, you will need to return to it after the Secondary Prisms are configured. Secondary Prism Configuration Repeat this procedure for each Secondary Prism. Once all Secondary Prisms have been configured, go to the next chapter. Primary Prism Configuration Completion Use Load balancing Load balancing, which must be enabled by the Primary Prism, allows all Prisms in the Cluster not to exceed the maximum power of the system. It is NOT possible to install more than one Cluster on the same system. In case of installation of more than 30 Prisms on the same system contact Silla service. Set the maximum power Setting the maximum power should be done through the Guided Primary Prism Configuration. How load balancing works Load balancing adjusts the power of each Prism to avoid exceeding the maximum power. In particular, Prism will try to: Remember that by regulation the minimum power to be able to charge the car is: 1.4 kW in single phase 4 kW in three-phase If there is not this minimum power, charging will not start. RFID Authorization In case you want to authorize recharging through RFID cards, to allow recharging only to authorized users, follow the HoReCa Guide. Charging mode In case of Cluster, the charging mode will be modifiable only by the Primary Prism and will be the same for the whole Cluster. It is not possible to choose a different charging mode for each Prism in the Cluster. Normal Mode In Normal mode, the Prisms will use all the power they need, always staying below the maximum power of the meter. Solar mode In Solar mode, the Prisms will use only the excess power from the PV system that would be sold to the grid. Refer to the Prism Solar Installation, Operation and Maintenance Manual for more information on charging methods. Error handling Remember that by regulation the minimum power to be able to charge the car is: 1.4 kW in single phase 4 kW in three-phase If there is not this minimum power, charging will not start.<\/p>\n","protected":false},"author":34,"featured_media":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_uag_custom_page_level_css":"","footnotes":""},"doc_category":[],"doc_tag":[1747,1671,560],"class_list":["post-21409","docs","type-docs","status-publish","hentry","doc_tag-cluster-en","doc_tag-how-to-en","doc_tag-prism-en"],"year_month":"2026-05","word_count":1326,"total_views":0,"reactions":{"happy":0,"normal":0,"sad":0},"author_info":{"name":"veroweb","author_nicename":"veroweb","author_url":"https:\/\/silla.industries\/en\/author\/veroweb\/"},"doc_category_info":[],"doc_tag_info":[{"term_name":"Cluster","term_url":"https:\/\/silla.industries\/en\/docs-tag\/cluster-en\/"},{"term_name":"How to...","term_url":"https:\/\/silla.industries\/en\/docs-tag\/how-to-en\/"},{"term_name":"Prism","term_url":"https:\/\/silla.industries\/en\/docs-tag\/prism-en\/"}],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"betterdocs-category-thumb":false,"post-thumbnail":false,"twentytwenty-fullscreen":false,"mailpoet_newsletter_max":false,"menu-26x26":false,"menu-36x36":false,"menu-48x48":false,"woocommerce_thumbnail":false,"woocommerce_single":false,"woocommerce_gallery_thumbnail":false},"uagb_author_info":{"display_name":"veroweb","author_link":"https:\/\/silla.industries\/en\/author\/veroweb\/"},"uagb_comment_info":0,"uagb_excerpt":"Introduction Cluster is the functionality that allows multiple Prisms to communicate with each other when connected to the same system. This functionality is critical for: Cluster functionality is available from version 2.7.X.If your Prisms have a lower version, connect them to the Internet and perform an upgrade (follow the Prism installation manual) Design of a&hellip;","knowledge_base_info":[],"knowledge_base_slug":[],"_links":{"self":[{"href":"https:\/\/silla.industries\/en\/wp-json\/wp\/v2\/docs\/21409","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/silla.industries\/en\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/silla.industries\/en\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/silla.industries\/en\/wp-json\/wp\/v2\/users\/34"}],"replies":[{"embeddable":true,"href":"https:\/\/silla.industries\/en\/wp-json\/wp\/v2\/comments?post=21409"}],"version-history":[{"count":0,"href":"https:\/\/silla.industries\/en\/wp-json\/wp\/v2\/docs\/21409\/revisions"}],"wp:attachment":[{"href":"https:\/\/silla.industries\/en\/wp-json\/wp\/v2\/media?parent=21409"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/silla.industries\/en\/wp-json\/wp\/v2\/doc_category?post=21409"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/silla.industries\/en\/wp-json\/wp\/v2\/doc_tag?post=21409"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}