{"id":1144,"date":"2020-12-27T15:20:40","date_gmt":"2020-12-27T14:20:40","guid":{"rendered":"https:\/\/silla.industries\/energy-storage-systems\/"},"modified":"2025-06-30T21:11:13","modified_gmt":"2025-06-30T19:11:13","slug":"energy-storage-systems","status":"publish","type":"page","link":"https:\/\/silla.industries\/en\/energy-storage-systems\/","title":{"rendered":"Energy Storage Systems"},"content":{"rendered":"\n<p>In the case of systems equipped with a storage system, Prism varies its behaviour depending on how it is installed; two different scenarios are possible. <\/p>\n\n<h4 class=\"wp-block-heading\">Prism with storage priority<\/h4>\n<div class=\"wp-block-image\">\n<figure class=\"alignleft size-medium\"><img decoding=\"async\" width=\"165\" height=\"300\" src=\"https:\/\/silla.industries\/wp-content\/uploads\/2021\/01\/Silla-Prism-charging-interface-165x300.jpg\" alt=\"Silla&#x2019;s Prism charging interface\" class=\"wp-image-368\" srcset=\"https:\/\/silla.industries\/wp-content\/uploads\/2021\/01\/Silla-Prism-charging-interface-165x300.jpg 165w, https:\/\/silla.industries\/wp-content\/uploads\/2021\/01\/Silla-Prism-charging-interface-600x1088.jpg 600w, https:\/\/silla.industries\/wp-content\/uploads\/2021\/01\/Silla-Prism-charging-interface-565x1024.jpg 565w, https:\/\/silla.industries\/wp-content\/uploads\/2021\/01\/Silla-Prism-charging-interface-768x1393.jpg 768w, https:\/\/silla.industries\/wp-content\/uploads\/2021\/01\/Silla-Prism-charging-interface-847x1536.jpg 847w, https:\/\/silla.industries\/wp-content\/uploads\/2021\/01\/Silla-Prism-charging-interface.jpg 1055w\" sizes=\"(max-width: 165px) 100vw, 165px\" \/><\/figure>\n<\/div>\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"512\" height=\"401\" src=\"https:\/\/silla.industries\/wp-content\/uploads\/2022\/01\/immagine_2022-01-18_225415.png\" alt=\"\" class=\"wp-image-5320\" srcset=\"https:\/\/silla.industries\/wp-content\/uploads\/2022\/01\/immagine_2022-01-18_225415.png 512w, https:\/\/silla.industries\/wp-content\/uploads\/2022\/01\/immagine_2022-01-18_225415-300x235.png 300w, https:\/\/silla.industries\/wp-content\/uploads\/2022\/01\/immagine_2022-01-18_225415-77x60.png 77w, https:\/\/silla.industries\/wp-content\/uploads\/2022\/01\/immagine_2022-01-18_225415-115x90.png 115w\" sizes=\"(max-width: 512px) 100vw, 512px\" \/><\/figure>\n\n<p>In this case, the energy storage system will not detect Prism&#8217;s consumption.<\/p>\n\n<ul class=\"wp-block-list\">\n<li>In <strong>Solar<\/strong> mode, the storage battery will be charged first; once it reaches 100% and excess production from the PV system is detected, Prism will start charging the vehicle.  <\/li>\n\n\n\n<li>In <strong>Normal<\/strong>mode, Prism will not withdraw energy from the battery, but only from the grid and from any excess of solar energy when the storage\u2019s battery is fully charged. The consumption of Prism will not be detected or counted by the storage system. The consumption of Prism will not be detected or counted by the storage system.<\/li>\n<\/ul>\n\n<h4 class=\"wp-block-heading\">Prism with car charging priority<\/h4>\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"512\" height=\"401\" src=\"https:\/\/silla.industries\/wp-content\/uploads\/2022\/01\/immagine_2022-01-18_225922.png\" alt=\"\" class=\"wp-image-5322\" srcset=\"https:\/\/silla.industries\/wp-content\/uploads\/2022\/01\/immagine_2022-01-18_225922.png 512w, https:\/\/silla.industries\/wp-content\/uploads\/2022\/01\/immagine_2022-01-18_225922-300x235.png 300w, https:\/\/silla.industries\/wp-content\/uploads\/2022\/01\/immagine_2022-01-18_225922-77x60.png 77w, https:\/\/silla.industries\/wp-content\/uploads\/2022\/01\/immagine_2022-01-18_225922-115x90.png 115w\" sizes=\"(max-width: 512px) 100vw, 512px\" \/><\/figure>\n\n<p>Prism is installed downstream of the storage sensor.<\/p>\n\n<p>In this configuration, Prism will have the solar energy consumption priority over the energy storage system, which will start charging only when the car stops charging because the battery is charged, or due to limits set by the user. <\/p>\n\n<ul class=\"wp-block-list\">\n<li>In <strong>Solar<\/strong> mode, the car&#8217;s battery will first be charged using excess solar production and, if it is not enough, drawing power from the storage battery up to the current limit set by the user.  <\/li>\n\n\n\n<li>In <strong>Normal<\/strong> mode, Prism will draw energy from storage, or from the grid, up to the current limit set by the user.<\/li>\n<\/ul>\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"wp-block-buttons is-horizontal is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-03627597 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/silla.industries\/en\/shop\/\" style=\"border-radius:10px\" target=\"_blank\" rel=\"noreferrer noopener\">visit our shop<\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>In the case of systems equipped with a storage system, Prism varies its behaviour depending on how it is installed; two different scenarios are possible. Prism with storage priority In this case, the energy storage system will not detect Prism&#8217;s consumption. Prism with car charging priority Prism is installed downstream of the storage sensor. In this configuration, Prism will have the solar energy consumption priority over the energy storage system, which will start charging only when the car stops charging because the battery is charged, or due to limits set by the user.<\/p>\n","protected":false},"author":23,"featured_media":0,"parent":0,"menu_order":37,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_uag_custom_page_level_css":"","footnotes":""},"class_list":["post-1144","page","type-page","status-publish","hentry"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"betterdocs-category-thumb":false,"post-thumbnail":false,"twentytwenty-fullscreen":false,"mailpoet_newsletter_max":false,"menu-26x26":false,"menu-36x36":false,"menu-48x48":false,"woocommerce_thumbnail":false,"woocommerce_single":false,"woocommerce_gallery_thumbnail":false},"uagb_author_info":{"display_name":"Valentina De Simone","author_link":"https:\/\/silla.industries\/en\/author\/valentina\/"},"uagb_comment_info":0,"uagb_excerpt":"In the case of systems equipped with a storage system, Prism varies its behaviour depending on how it is installed; two different scenarios are possible. Prism with storage priority In this case, the energy storage system will not detect Prism&#8217;s consumption. Prism with car charging priority Prism is installed downstream of the storage sensor. In&hellip;","_links":{"self":[{"href":"https:\/\/silla.industries\/en\/wp-json\/wp\/v2\/pages\/1144","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/silla.industries\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/silla.industries\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/silla.industries\/en\/wp-json\/wp\/v2\/users\/23"}],"replies":[{"embeddable":true,"href":"https:\/\/silla.industries\/en\/wp-json\/wp\/v2\/comments?post=1144"}],"version-history":[{"count":0,"href":"https:\/\/silla.industries\/en\/wp-json\/wp\/v2\/pages\/1144\/revisions"}],"wp:attachment":[{"href":"https:\/\/silla.industries\/en\/wp-json\/wp\/v2\/media?parent=1144"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}